4P Pole DC Spd Type 2 3 Phase Maximum Backup Fuse 125A For Low Voltage
Product Details:
Place of Origin: | Dongguan China |
Brand Name: | Uchi |
Certification: | CE / SGS / ISO9001 |
Model Number: | OBV5-C40 |
Payment & Shipping Terms:
Minimum Order Quantity: | 200 piece |
---|---|
Price: | Negotiate |
Packaging Details: | export package / Negotiate |
Delivery Time: | 5-15 days after payment |
Payment Terms: | T/T, L/C, Western Union |
Supply Ability: | 60000 pieces per month |
Detail Information |
|||
Name: | Surge Protector | Material: | PBT/Nylon/VDR |
---|---|---|---|
Poles Number: | 4P | Color: | White |
Uc: | 385/420/440V | CertificationCE,CQC: | CE / CQC / SGS |
Function: | Lightning Protection For Low Voltage | ||
High Light: | arrester 3 phase for Low Voltage,Maximum backup fuse 125A DC spd type 2,4P Pole DC spd type 2 |
Product Description
Wholesale 3 Phase 20-40ka 385V Type 2 Surge Protector for Low Voltage
According to the standard elevator power distribution cabinet, it is necessary to install a surge protector, and the elevator is responsible for carrying people and objects, which is very important, and the lightning protection of the elevator power distribution system should be paid more attention.
In the lightning protection of the building power distribution system, the elevator machine room belongs to the three-level lightning protection or the last-level lightning protection (the main power distribution level one, the floor distribution level two, and the elevator machine room three level).
Since the surge protector is installed to protect the equipment of the elevator motor controller, the residual voltage or protection level of the surge protector in the elevator cannot be high. When the residual voltage is high, the lightning protector will also play a role, but the elevator Still beaten by thunder.
According to the standard elevator lightning surge protector, products with protection level Up: 1.2KV should be selected (the residual voltage value will be slightly lower than the protection level), and the protection level of the elevator surge protector will also be paid attention to in the lightning protection acceptance of the Meteorological Bureau , Which is the Up value.
Therefore, the elevator selection lightning protection device must pay attention to this point.
OBV5-C40
The surge arrestors OBV5-C40-LT meet the type 2 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions. The use of high-performance varistors permits a rapid response time and a low protection level, without any line follow current. If circumstances are uncertain and there is a risk of fire from an overload, the internal cut-off unit disconnects the arrestor from the mains if necessary. In addition, the QR code printed on the arrestor allows disary. In addition, the QR code printed on the arrestor allows direct access to the online installation instructions.
Technical Parameters
Model: OBV5-C40 | |||
Maximum continuous voltage AC | Uc | V | 275/320/385/440 |
SPD to EN 61643-11 | Type 2 | ||
SPD to IEC 61643-1 | class II | ||
Nominal discharge current (8/20< s) | In | kA | 20 |
Maximum discharge current (8/20< s) | Imax | kA | 40 |
Voltage protection level | Up | kV | < 1,3/1,5/1,8/2,0 |
Response time | tA | ns | < 25 |
Maximum back-up fuse | A | 125 | |
Temperature range | ϑ | ℃ | -40℃~+85℃ |
Protection rating | IP 20 | ||
Max. cable cross-section flexible (fine-wire) | mm² | 25 | |
Max. cable cross-section rigid (single wire/multi-wire) | mm² | 35 |
Feature&Benefits
1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact.
·IP20 finger-safe designVisual indicator.
·Small foot print.
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Others
Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Transient voltage surgesin lv power lines
Transient overvoltages are voltage surges that can reach tens ofkilovolts with a duration of the order of microseconds.Despite theirshort duration, the high energy content can cause serious problemsto equipment connected to the line, from premature aging to destruction, causing disruptions to service and financial loss.Thistype of surge can have various different causes, including atmospheric lightning directly striking the external protection(lightning rods) on a building or transmission line or the associatedinduction of electromagnetic fields on metallic conductors.
Outdoor and longer lines are the most exposed to these fields,which often receive high levels of induction.
It is also common for non-weather phenomena, such as transformer centre switching or the disconnection of motors orother inductive loads to cause voltage spikes in adjacent lines.
Although a lower current is induced,the effect produced is equally or moredestructive, due to the greatersensitivity of electronic equipmentconnected to communications lines(telephone, Ethernet, R, etc.).
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.
External protection (ESE lightning rods and faradization).System for protection against direct lightningstrike.These capture the lightning within the protectedarea and lead it, in a controlled manner, safely to ground. Internal protection (power frequency overvoltage andsurge protection devices). Equipment designed to protectagainst the effects of overvoltages in equipment connected to the power supply systems and/orcommunications networks.Grounding systems (grounding and insulation monitoring).Systems that allow atmospheric dischargecurrents to be dispersed into the ground. The need formonitoring the grounding system.CUAJE offers a widerange of products for each of these systems. It alsodevelops custom products, provides advice and consultingservices and the best possible aftersales service.
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.