• AC 180V Surge Box Protector Imax 200kA Wire Connection 350x260x130mm
AC 180V Surge Box Protector Imax 200kA Wire Connection 350x260x130mm

AC 180V Surge Box Protector Imax 200kA Wire Connection 350x260x130mm

Product Details:

Place of Origin: Dongguan China
Brand Name: Uchi
Certification: CE / ISO9001 / FCC / SGS
Model Number: Power lightning protection box

Payment & Shipping Terms:

Minimum Order Quantity: 50 piece / pieces
Price: Negotiate
Packaging Details: Export package
Delivery Time: 8 - 15 days after payment
Payment Terms: T/T, L/C
Supply Ability: 10000 pieces per month
Get Best Price Contact Now

Detail Information

AC: 180V/320V Protection Level Up: 1.5kV
Nominal Discharge Current In(8/20μs): 50kA Maximum Discharge Current Imax (8/20μs): 50kA Or 200kA
Product Warranty: 1 Year Application: Solar Power System , Industrial
High Light:

AC 180V surge box protector

,

200kA surge box protector

,

350x260x130mm wire connection box

Product Description

AC 180V Surge Box Protector Imax 200kA Wire Connection 350x260x130mm

AC 180V/320V Power Lightning Protection Box For Solar Power System , Industrial

 

 

Product Category(GB/IEC)   Class I+II/ Type 1+2
Protection mode   Full protection mode
Product technologies   ESG technology (pre-stage) + VTD technology (post-stage); LC filter technology; thermal trip technology; built-in series overcurrent protection
Applicable power distribution system Un 120/208V to 127/220V Three-phase (TN/TT) 220/380V to 277/480V Three-phase (TN/TT)
Maximum sustainable working voltage (AC) Uc 180V 320V
Rated load current IL 400A
Nominal discharge current In 50kA (8/20μs)
Pre-stage surge protection capability L-N   Iimp: 50kA (10/350μs), Imax: 150kA (8/20μs)
N-PE   Iimp: 100kA (10/350μs), Imax: 200kA (8/20μs)
Post-level surge protection capability L-N Imax 50kA (8/20μs)
Surge discharge capacity (each phase) Imax 200kA (8/20μs)
Voltage protection level L-N@6kV/3kA VPR ≤ 0.4kV ≤ 0.5kV
L-N@In(50kA, 8/20μs) Up ≤ 0.8kV ≤ 1.0kV
N-PE@1.2/50μs Up ≤ 1.0kV ≤ 1.5kV
Working current IPE <0.1mA
Pressure drop   < 2V,At rated load current
Temporary overvoltage characteristics-withstand mode Utov 230V/120min 440V/120min

 

Scope of application:


The second-level lightning protection box is mainly installed in the floor power distribution, computer room power distribution and other environments, as the second-level lightning protection of the power distribution system, discharges the remaining surge, and cooperates with the first-level lightning protection box to meet the lightning protection acceptance Requirements and protection needs.

 

The main parameters:


Maximum continuous working voltage Uc: 385VAC
Nominal discharge current In(8/20μs): 20kA or 40kA
Maximum discharge current Imax (8/20μs): 40kA or 80kA
Protection level Up: 1.8kV or 2.1kV
Protection mode: three-phase 4P, single-phase 2P
Product size: 350*260*130mm

 

Product Description:


Adopting Class II SPD to combine “3+1” circuit, protecting low voltage equipment from surge damages, applied in TT system, designed according to IEC61643-1/GB 18802.1
Main character:
1. Green light indicates normal and red light indicates fault for operation

2. Built-in circuit breaker, and thermal disconnection device, when the fault occurred, the thermal disconnection device will cut off the SPD from the power net, the green window will change
3. Impulse counter function, recording the lightning events
4. External wiring terminal, easy for connection, suitable for indoor application

 

Type   BT 5L CM 275/40 4P BT 5L CM 385/40 4P BT 5L CM 275/40 3+1 BT 5L CM 385/40 3+1
Order No.   840 883 840 887 840 884 840 888
Norminal a.c. voltage UN 230V/400V 230V/400V 230V/400V 230V/400V
Rated voltage (max. continuous a.c voltage) L/N Uc 275V 385V 275V 385V
Rated voltage (max. continuous a.c voltage) N/PE Uc 275V 385V 255V 255V
Nominal discharge current (8/20µs) L/N In 20KA 20KA 20KA 20KA
Nominal discharge current (8/20µs) N/PE In 20KA 20KA 40KA 40KA
Max. discharge current (8/20µs) L/N Imax 40KA 40KA 40KA 40KA
Max. discharge current (8/20µs) N/PE Imax 40KA 40KA 65KA 65KA
Voltage protection level L/N Up ≤1.25KV ≤1.8KV ≤1.25KV ≤1.8KV
Voltage protection level N/PE Up ≤1.25KV ≤1.8KV ≤1.5KV ≤1.5KV
Follow current extinguishing capability at Uc (N/E) IL     100Arms 100Arms
Operating temperature range   -40℃…+80℃
Cross-sectional area   25mm2 solid/35mm2 flexible
Enclosure material   black metal housing (die-casting Aluminum)
Test standards   YD/T 1235.1; GB 18802.1; IEC 61643-1
Certification   CE (LVD, EMC)

 


AC 180V Surge Box Protector Imax 200kA Wire Connection 350x260x130mm 0

 

Want to Know more details about this product
I am interested in AC 180V Surge Box Protector Imax 200kA Wire Connection 350x260x130mm could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.